Environmental Acronym of the Month: UST or Underground Storage Tank
This month, we’re digging into an environmental acronym that frequently comes up during commercial real estate due diligence: UST, or Underground Storage Tank.
Underground storage tanks are more common than you might think, and understanding their history, purpose, potential environmental impacts, and regulatory requirements is an important part of evaluating commercial and industrial properties.
What Is a UST?
An Underground Storage Tank (UST) is a tank and associated underground piping system used to store liquids, with at least 10% of the combined volume located beneath the ground’s surface, as defined by the U.S. Environmental Protection Agency (EPA).
USTs are most commonly associated with gasoline stations, where they store fuel before it’s pumped into vehicles. However, they’ve also been used at automotive repair facilities, manufacturing plants, commercial buildings, and other properties to store petroleum products, heating oil, and certain chemicals.
While many USTs remain actively in use today, others have been removed, closed in place, or simply forgotten as properties changed ownership and use over the years.
How Are USTs Found and Identified?
Because USTs are buried underground, identifying them often requires a combination of historical research, property inspections, and specialized equipment.
- Historical Records Research: Environmental professionals review historical aerial photographs, fire insurance maps, regulatory databases, and property records to identify past uses that may indicate the presence of underground tanks.
- Site Inspections: During a property inspection, environmental professionals look for physical clues such as fill pipes, vent pipes, concrete pads, or other features that may suggest a UST is or was present.
- Geophysical Surveys: When a suspected tank cannot be confirmed through records or visual inspection, specialized equipment such as ground-penetrating radar (GPR) or electromagnetic instruments may help locate buried tanks and other underground features.
Together, these methods help environmental professionals piece together a property’s history and determine whether further investigation is warranted.
Why Can USTs Be an Environmental Concern?
The presence of a UST doesn’t automatically indicate contamination. Many tanks operate safely for years with proper maintenance, monitoring, and regulatory oversight.
However, older tanks, particularly those that were not properly maintained or closed, can develop leaks that release petroleum products or other stored substances into surrounding soil and groundwater.
When a release occurs, the extent of contamination depends on several factors, including the substance stored, the duration of the release, and the surrounding soil and groundwater conditions.
For commercial real estate transactions, understanding a tank’s history and condition helps buyers, lenders, and property owners evaluate potential environmental liabilities and determine whether additional investigation is necessary.
California UST Regulations: “Use It or Lose It”
In California, underground storage tanks are subject to strict regulatory requirements designed to prevent leaks and protect soil and groundwater.
One important consideration for property owners is the concept commonly referred to as “Use It or Lose It.” Under California’s temporary closure requirements, a UST that has been taken out of service cannot necessarily remain inactive indefinitely and then be returned to operation without meeting additional regulatory requirements.
Generally, temporary closure is limited to 12 months unless an extension is approved by the appropriate regulatory agency. Returning a tank to service after an extended period of inactivity may require demonstrating compliance with applicable new-tank or upgrade requirements.
Importantly, all regulated USTs that remain in use must meet applicable California upgrade requirements, regardless of how frequently they are used. Simply keeping a tank operational does not exempt a property owner from required upgrades, leak detection, monitoring, testing, or maintenance.
California has also implemented significant requirements affecting older, single-walled UST systems.
Under California Health and Safety Code Section 25292.05, regulated single-walled UST systems, including applicable single-walled piping, were required to be permanently closed by December 31, 2025.
As of January 1, 2026, systems subject to this requirement that were not properly closed are out of compliance and cannot legally operate. Owners and operators may face enforcement actions, including restrictions on fuel deliveries and dispensing, as well as civil penalties.
For property owners, this means an older UST may represent more than a potential contamination concern. It may also create regulatory compliance obligations, tank replacement or closure costs, and potential complications during property transactions or redevelopment.
Understanding whether a UST is active, temporarily closed, properly upgraded, or subject to permanent closure requirements is therefore an important part of environmental due diligence.
What Happens If a UST Is Found?
Finding a UST doesn’t necessarily mean extensive cleanup is required. The next steps depend on the tank’s condition, whether it remains in use, its regulatory compliance status, and whether there is evidence of a release.
Depending on the circumstances, the process may include:
- Assessment: Reviewing available tank records, evaluating regulatory compliance, and conducting soil or groundwater sampling, when warranted, to determine whether contamination is present.
- Tank Closure or Removal: Properly closing or removing an unused or noncompliant tank in accordance with applicable regulations, often with oversight from the appropriate regulatory agency.
- Remediation: If contamination is identified, cleanup methods may include removing impacted soil, treating contaminated groundwater, or using other site-specific remediation technologies.
- Documentation and Regulatory Closure: Preparing the necessary reports and working with regulatory agencies to document the work performed and, when applicable, obtain regulatory closure.
Not every UST requires remediation, and cleanup approaches vary depending on site conditions and regulatory requirements. In many cases, identifying and addressing a concern early can help minimize complications later in the transaction or redevelopment process.
The Bottom Line
Underground storage tanks are an important piece of a property’s environmental history, but their presence doesn’t automatically spell trouble.
In California, however, understanding a UST’s regulatory status is just as important as understanding its environmental condition. All regulated tanks that remain in operation must meet applicable upgrade requirements, and older single-walled systems subject to California’s December 31, 2025, closure deadline can no longer legally operate.
With thorough historical research, appropriate investigation, and a clear understanding of regulatory compliance, closure, and remediation options, UST-related concerns can often be evaluated and managed effectively.
At McAlister GeoScience, Inc., we help property owners, buyers, lenders, and developers navigate environmental due diligence, from identifying potential USTs during Phase I Environmental Site Assessments to conducting subsurface investigations and supporting remediation efforts.
Whether you’re purchasing, financing, or redeveloping a property, understanding what’s beneath the surface is a good place to start.